News

Why Is The Flow Rate Significantly Reduced After The Automatic Self-cleaning Filter Is Installed?

Apr 10, 2025 Leave a message

Table of contents

 

1. Introduction


2. Overview of the working principle of the automatic self-cleaning filter


3. Analysis of the reasons for the significant reduction in flow after installation


4. Solutions and suggestions


5. Conclusion

 

1. Introduction

 

The Auto Self Cleaning Strainer is highly favored in the fields of sewage treatment, industrial circulating water, agricultural irrigation and civil drinking water purification due to its high-efficiency filtration and automatic cleaning characteristics. It can effectively intercept impurities in the water and ensure the stable operation of subsequent equipment and water quality. However, in actual installation and use, many users reported that the flow rate dropped significantly after installation, which not only weakened the performance of the filter, but also interfered with the normal operation of the entire water system.

 

2. Overview of the working principle of the automatic self-cleaning filter

 

 automatic self-cleaning filter

 

The automatic self-cleaning filter mainly relies on the filter to intercept impurities in the water flow. During normal operation, water flows in from the water inlet, is filtered through the filter, and impurities larger than the filter aperture are intercepted, and the filtered water flows out from the water outlet. As it is used, impurities accumulate on the surface of the filter, causing a pressure difference between the inlet and outlet of the filter. When the pressure difference reaches the set value, the automatic self-cleaning system starts. Common examples include a motor driving a brush to scrub the filter, while opening the drain valve to discharge impurities, restore the filter to transparency, and maintain the normal operation of the filter. Its automation and high efficiency effectively guarantee water quality and system stability. Once the flow reduction problem occurs after installation, it needs to be checked from all aspects of the work process.

 

3. Analysis of the reasons for the significant reduction in flow after installation

 

Improper filter selection​


Diameter mismatch​


If the diameter of the selected Auto Backwash Self Cleaning Filter is smaller than the actual water flow demand, the water flow resistance will be greatly increased. For example, in an industrial circulating water system, the actual flow rate is 500 cubic meters per hour, but the filter that can only meet 300 cubic meters per hour is mistakenly selected, which will inevitably lead to the obstruction of water flow in the filter and a sharp drop in the outlet flow. According to statistics, the flow reduction caused by diameter mismatch in industrial projects accounts for about 15%. In industries such as chemical industry and agricultural irrigation, such problems are common, affecting production and crop growth. ​


Excessive filtration accuracy​


Excessive pursuit of high-precision filtration and the selection of filters with a precision far exceeding the actual demand can finely filter impurities, but the pores of the filter are too small, which greatly increases the difficulty of water flow. For example, electronic chip manufacturing companies actually need a filtration accuracy of 50 microns, but use 10 micron precision filters, resulting in a sharp drop in flow after installation, affecting the water supply of the production line. Excessive precision also makes the filter easy to clog, reducing the effective water flow area. In areas with complex water quality, the flow will drop significantly in a short time.​


Installation problems​


Improper pipe connection​


Improper connection between pipe and filter during installation, such as eccentric interface and loose seal, will increase local water flow resistance. In the cooling water treatment system of central air-conditioning in commercial buildings, the eccentricity of 5 mm at the interface will cause turbulence in the water flow, resulting in a reduction of about 20% in the filter outlet flow. Loose sealing not only leaks water, but also allows air to enter the pipe to form air blockage, affecting the flow. In the water supply system of high-rise buildings, this problem seriously affects the water use of high-rise residents. ​


Improper filter installation position​


If the filter is installed at the bend of the pipe, in a narrow section, or near equipment that hinders the water flow, it will destroy the uniformity and stability of the water flow and increase the resistance. In the cooling circulating water pipeline of the factory, the filter is only 0.5 meters away from the elbow. The turbulence at the elbow extends to the filter, increasing its inlet and outlet pressure difference and reducing the flow by about 18%. In a complex pipeline layout, an unreasonable installation position may also prevent the filter from fully utilizing the system pressure energy, resulting in insufficient actual working pressure and affecting the flow.​

 

Filter blockage​


Poor raw water quality​


Excessive impurities, particulate matter, and suspended matter in the raw water will cause the filter to accumulate a large amount of impurities in a short period of time, block the filter, reduce the water flow area, and reduce the flow rate. Due to poor initial treatment, the recycled water of the printing and dyeing factory contains a large amount of dye particles and fiber impurities. The installed filter was severely blocked within a week, and the flow rate was reduced by more than 60%. In areas where surface water is used as a water source, the sediment content of raw water increases greatly during the rainy season. If the filter cannot adapt, the filter is very easy to block, affecting normal production and living water. ​

 

Cleaning system failure​


Automatic self-cleaning filter cleaning system failure, such as damage to the cleaning motor, wear of the brush and inability to effectively clean the filter, and failure of the drain valve to discharge impurities in time, will lead to incomplete cleaning of the filter, continuous accumulation of impurities and eventually blocking the filter. In the industrial water treatment system of the steel plant, the cleaning motor drive chain broke, causing the cleaning brush to be unable to rotate. Within a week, the filter flow rate dropped from 400 cubic meters per hour to 150 cubic meters. Improper cleaning cycle setting also affects the cleaning effect. If the cleaning cycle is too long, the filter will be easily blocked, and if it is too short, the equipment will be worn and the flow stability will be affected. ​


 Pressure problem​


Insufficient inlet pressure​


The inlet pressure at the front end of the filter is lower than the design requirements, and the water flow lacks power to pass through the filter, resulting in a reduction in flow. In the secondary water supply system of old residential areas, due to aging of the water pump and pipeline loss, the water pressure entering the filter is only 0.1MPa, which is far lower than the designed 0.3-0.5MPa, causing the tap water output in residents' homes to become smaller. In agricultural irrigation projects with long-distance water transmission, the pressure loss along the pipeline causes insufficient inlet pressure of the filter, affecting the flow demand of irrigation equipment. Statistics show that in the field of civil and agricultural water use, about 25% of the filter flow reduction problems are caused by insufficient inlet pressure. ​


System back pressure is too high​


The back pressure of the system at the back end of the filter is too high, such as the downstream valve of the pipeline is not fully opened, the pipeline is blocked, the resistance of the water-using equipment is too large, etc., which will make the water flow at the filter outlet unsmooth and affect the inlet flow. In the hotel's hot water supply system, scale clogged the hot water taps on some floors, causing the back pressure of the pipes to increase, and the flow of the Automatic Self Cleaning Strainers in the machine room decreased by about 22%, affecting the hotel's hot water supply. In industrial production, when subsequent process equipment has special requirements for water flow pressure, changes in system back pressure will also affect the normal flow of the filter.

 

4. Solutions and suggestions

 

Correct selection​


According to the actual water flow, water quality and system pressure and other parameters, accurately calculate the required filter diameter and filtration accuracy. Industrial projects can refer to the water requirements of process equipment and pipeline hydraulic calculations. Civil buildings need to consider factors such as the number of households and peak water flow, and select models based on industry standards and engineering experience. ​


For water sources with complex water quality and large fluctuations in impurity content, select filters with adjustable filtration accuracy, flexibly adjust the accuracy, and ensure the filtration effect and reasonable flow. At the same time, ensure that the self-cleaning ability of the filter matches the impurity content of the raw water to ensure that the cleaning system effectively responds to impurity accumulation. ​


Standardized installation​


The installer strictly follows the filter installation instructions to ensure that the pipeline and filter are connected accurately and well sealed. Carefully check the flatness and concentricity of the interface before connection, and repair or adjust the deviation interface. Select suitable sealing materials and tighten the connecting bolts according to the specified torque to prevent water leakage and air blockage. ​


Reasonably plan the installation location of the filter, select it in the straight section of the pipeline, away from elbows, valves, water pumps and other equipment that affect water flow. The installation location should also be convenient for later maintenance and repair to ensure convenient

maintenance operations.​


Strengthen maintenance management​


Establish a complete filter maintenance management system, regularly check the filter blockage, cleaning system operation and wear of various components. According to the raw water quality and actual operation conditions, reasonably adjust the cleaning cycle to ensure the filter is transparent. ​
When the raw water quality is poor, pre-treatment equipment such as sedimentation tanks and coarse filters can be added to the front of the filter to reduce the impurity content in the water, reduce the burden on the filter, extend the life of the filter, and ensure stable flow. At the same time, regularly maintain the pre-treatment equipment to ensure its normal operation. ​


Real-time monitoring and early warning​


Install flow monitoring equipment to monitor the flow changes in the inlet and outlet of the filter in real time, and combine pressure monitoring data to detect flow abnormalities in time. Through data analysis, quickly determine the cause of flow reduction, such as filter blockage, pressure changes, etc. When the flow or pressure fluctuates abnormally, the system will issue an early warning in time to remind management personnel to deal with it. ​
Use the intelligent management system to record and analyze the filter operation data for a long time and establish an equipment operation database. Through big data analysis, predict possible failures of the filter, take maintenance measures in advance, and avoid equipment failures affecting production and life. For example, analyze historical data to predict the filter blockage cycle and arrange cleaning and maintenance work in advance.

 

5. Conclusion

 

The significant reduction in flow after the automatic self-cleaning filter is installed is caused by multiple factors such as filter selection, installation, operation and maintenance, and system pressure. Through in-depth analysis of the causes, targeted solutions and suggestions are proposed. In practical applications, users should pay attention to the selection and installation links, strengthen daily maintenance management, use advanced monitoring technology to monitor the operating status of the filter in real time, and solve problems such as flow reduction in a timely manner to ensure its stable and efficient operation, and provide reliable water quality assurance and flow support for industrial production and residents' lives. With the development of technology, the performance and reliability of automatic self-cleaning filters will continue to improve, and it is expected to reduce the occurrence of such problems through smarter and more efficient design and management.

 

 

Send Inquiry