Product Features
High Flow Capacity
The High Capacity Self Cleaning Filter is available in DN80–DN600 nominal pipe sizes, covering economical flow rates from 45 to 2,350 m³/h. This range allows the filtration configuration to be matched to different pipeline flow requirements in circulating and non-circulating water systems.
Automatic Cleaning with Continuous Water Supply
The filter automatically initiates cleaning based on filtration time or differential pressure, removing accumulated contaminants without routine manual filter-element removal. During the cleaning and drainage process, the main water supply can continue without requiring a bypass. Manual cleaning control is also available when required.
Adjustable Filtration Accuracy
The standard filtration accuracy is 100 μm, with selectable filtration ratings from 50 to 3,000 μm. The filtration rating can therefore be specified according to the particle-removal requirements of the water system and the equipment being protected.
Integrated Differential Pressure Monitoring
A differential pressure switch monitors the pressure difference across the filter during operation. When the preset differential-pressure condition is reached, the controller can initiate the cleaning cycle automatically. This allows the cleaning process to respond to contaminant accumulation rather than depending only on a fixed cleaning schedule.

Technical Specifications
| Parameter | Specification |
|---|---|
| Product Type |
|
| Filtration Accuracy | 100 μm standard |
| Selectable Filtration Accuracy | 50–3,000 μm |
| Working Voltage | AC 380 V, 50 Hz |
| Minimum Working Pressure | 0.1 MPa |
| Maximum Working Pressure | 1.6 MPa |
| Nominal Pipe Size | DN80–DN600 |
| Economical Flow Rate | 45–2,350 m³/h |
| Filter Area | 1,165–42,295 cm² |
| Drain Valve Outlet | DN40–DN80 |
| Discharge Time | 10–60 s |
| Cleaning Control | Automatic / Manual |
| Automatic Cleaning Trigger | Filtration Time / Differential Pressure |
| Standard Cleaning Element | Stainless Steel Brush |
| Connection | Flange |
| Standard Flange | National Standard Flange |
| Standard Operating Water Temperature | ≤95°C |
Core Components
- Filter Element Assembly - Retains suspended particles on the filtration surface during normal filtration.
- Cleaning Mechanism - Removes accumulated contaminants from the filter element during the cleaning cycle.
- Drive Mechanism - Operates the cleaning mechanism according to the configured cleaning cycle.
- Differential Pressure Switch - Monitors the pressure difference and provides the signal for differential-pressure-triggered cleaning.
- Electric Controller - Controls automatic and manual operation, cleaning parameters, and operating-status signals.
- Drain Valve - Discharges contaminants and wastewater removed during the cleaning process.
- Control Piping - Connects the control components for pressure monitoring, cleaning, and drainage functions.
- Connecting Flanges - Connects the filter to the process pipeline.
FAQ
Q1: Does the filter need to be removed for routine cleaning?
No. The integrated cleaning mechanism removes accumulated contaminants from the filter element during the automatic cleaning cycle, so routine cleaning does not require manual removal of the filter element.
Q2: What determines when the cleaning cycle starts?
The cleaning cycle can be triggered by a preset filtration time or differential pressure. The controller monitors the configured operating condition and starts cleaning when the corresponding setting is reached.
Q3: Can water continue flowing while the filter is being cleaned?
Yes. The main water supply can continue during the routine cleaning and drainage process, so a bypass is not required for this cleaning operation.
Q4: Does Hanzhikang support OEM and ODM customization for the filter?
Yes. Hanzhikang supports OEM and ODM projects for specific water filtration requirements. Customization can be discussed around flow rate, nominal pipe size, filtration accuracy, operating pressure, water temperature, cleaning control, drainage conditions, and other project-specific requirements. Buyers can provide system parameters, technical drawings, or application requirements for configuration assessment before production.
Q5: Where should the filter be installed in a water system?
The filter is normally installed upstream of the equipment requiring protection and connected in series with the process pipeline. The flow-direction marking on the filter should correspond to the actual water-flow direction.
Q6: What information should buyers provide when selecting a filter?
For a High Capacity Self Cleaning Filter, buyers should provide the required flow rate, nominal pipe size, filtration accuracy, operating pressure, water temperature, cleaning control requirements, and drainage conditions. These parameters provide the basis for selecting the appropriate filter configuration.
Hot Tags: high capacity self cleaning filter, China high capacity self cleaning filter manufacturers, suppliers, factory, custom liquid filter cartridge, liquid filter cartridge for diagnostic equipment, liquid filter cartridge for electronics, liquid filter cartridge for irrigation, liquid filter cartridge for tablets, liquid filters for industrial condensers