Product Description
| Operation parameters | Product Specifications | ||||||
| Maximum operating temperature | 1.2bar@190℃ | Outer diameter | 67.0mm | ||||
| Maximum forward withstand voltage | 4.3bar@25℃ | Inner diameter | 32.0mm | ||||
| Maximum reverse withstand voltage | 3.0bar@25℃ | Filter area | ≥0.74m² | ||||
| Recommended replacement pressure difference | 2.4bar@25℃ | ||||||
| Filter material | Product cleanliness | ||||||
| Filter media | Polytetrafluoroethylene (PTFE) | Metal dissolution | <25μg/device | ||||
| Support layer | PFA/PTFE | ||||||
| Sleeve/end cap | PFA | Particle leakage | <15个/10ml≥0.2μm | ||||
| Center rod | PFA | @5L/min DI water | |||||
| Connector | PFA | TOC recovery | <10ppb after flushing | ||||
| Sealing ring | Please refer to ordering information | (120 L@10L/min) | |||||
Technical Parameters
| Accuracy | Bubble point, 25℃ | Diffusion flow, 25℃ | ||||||
| 0.05μm | ≥2.4bar | ≤65ml/min@1.9bar | ||||||
| 0.1μm | ≥1.6bar | ≤40ml/min@1.2bar | ||||||
| 0.2μm | ≥1.0bar | ≤35ml/min@0.8bar | ||||||
| 0.45μm | ≥0.5bar | ≤30ml/min@0.4bar | ||||||
| 1.0μm | ≥0.3bar | - |
Flow rate-pressure difference diagram
PFA pleated filter elements use advanced technology and high-quality materials to create efficient filtration solutions. Tests of 10-inch filter elements with DI water at 20°C show that different precisions have different performances: 0.05μm filter elements have strong interception power and are suitable for high-precision scenarios such as semiconductors and high-end pharmaceuticals; 0.1μm and 0.2μm filter elements balance precision and flow rate, which is in line with conventional pure water filtration in the electronics industry; 0.45μm and 1.0μm filter elements have fast flow rates and low pressure differences, and can efficiently complete coarse filtration of food and beverages and initial purification of chemical raw materials. Multiple precision options meet the needs of multiple industries and are a reliable filtration choice.

Product application areas
Pharmaceutical and food industries: PFA perfluorinated filter elements have very little dissolution, and do not introduce impurities when filtering liquid medicines in pharmaceutical production, which meets the purity safety requirements; in the food and beverage field, they filter raw materials and purify water to prevent secondary pollution and protect food safety.
Electronics and semiconductor industries: The preparation of electronic ultrapure water requires high-precision filtration, and PFA perfluorinated filter elements accurately intercept particles; in semiconductor manufacturing, they rely on strong chemical tolerance to filter hydrofluoric acid, escort chip etching, and ensure product performance.
Chemical and petroleum industries: PFA perfluorinated filter elements are used in the chemical field to filter chemicals, which are resistant to corrosion such as strong acids and alkalis, and ensure stable structural performance; in the processing of oil and natural gas, their high temperature resistance is suitable for high-temperature exhaust gas and oil product filtration, promoting efficient and safe production



Our Factory
Our company's PFA perfluorinated filter elements support high customization and can be flexibly customized in terms of materials, precision, shape, size and performance according to the needs of different fields.
In the pharmaceutical field, with the extremely low dissolution characteristics of PFA, customized filter elements are used to ensure the purity and safety of liquid medicines; in the electronics industry, customized elements are used to accurately intercept impurities and safely filter reagents for the needs of high-precision filtration of ultrapure water and filtration of highly corrosive reagents for semiconductors; in the fields of environmental protection and energy, high-temperature resistant and corrosion-resistant filter elements are customized according to actual working conditions.
Choosing us will provide you with adaptation solutions to ensure product quality and process stability, reduce maintenance costs, and improve production efficiency and reliability with high-performance PFA perfluorinated filter elements.



Ordering Information
| Filter Media | Membrane Type | length | Accuracy | Connector Type | Sealing material | |||||||||
| CRAPTFE: Polytetrafluoroethylene membrane |
G = Hydrophobic L = Surface modified |
005=5 inches 010=10 inches 020=20 inches 030=30 inches 040=40 inches |
005=0.05μm 010=0.1μm 020=0.22μm 045=0.45μm 100=1.0μm |
0=DOE 2=222/Flat 3=222/Fin 6=226/Fin 7=226/Flat |
PV = Teflon coated fluororubber PS = Teflon coated silicone rubber |
|||||||||
FAQ
Q: Does the product comply with relevant international standards and certifications?
A: Our PFA perfluorinated filter element has passed FDA food contact material certification, USP Class VI pharmaceutical material certification, and ISO 13485 medical device quality management system certification, and is suitable for food and beverage, medicine, electronics and other fields. At the same time, it supports the provision of environmental compliance documents such as REACH and RoHS to ensure that the product meets the regulatory requirements of various regions around the world.
Q: What does the customized service include?
A: We can provide full customization of filter element length, outer diameter, interface form (such as flat mouth, quick connection, threaded interface), filtration accuracy, etc. according to customer needs. Support special function development, such as hydrophobic treatment and antibacterial coating addition, and provide sample solutions within 7 working days at the fastest to meet the needs of different application scenarios.
Q: What are the requirements for the transportation and storage of PFA perfluorinated filter element?
A: The filter element adopts anti-static and moisture-proof packaging to ensure that it is not damaged during transportation. It is recommended to store in a dry, ventilated, light-proof environment, with a temperature of 0 - 40°C and a relative humidity below 60%. Before long-term storage, it is recommended to rinse with pure water and dry to avoid residual pollutants affecting the performance of the filter element.
Q: Can you provide sample testing?
A: We support providing 1 - 2 samples for customer testing free of charge, and customers only need to bear the shipping costs. During the sample testing period, our technicians can follow up throughout the process, assist in analyzing the test data, optimize the product plan based on the test results, and ensure that the product is fully adapted to the actual needs of customers.